Difference between revisions of "Solar-h2o"

From Earlham CS Department
Jump to navigation Jump to search
(Copper Pipe Heat Exchanger Test)
(Developing a Solar Hot Water System at Miller Farm)
 
(13 intermediate revisions by 2 users not shown)
Line 1: Line 1:
==Current System==
+
==Developing a Solar Hot Water System at Miller Farm==
Our current hot water system uses LP gas and a hot water heater that was installed in 1998. 
 
  
After working on an energy audit of Miller Farm (our house) it has become clear that we use a huge amount of energy to heat our water.  Installing a solar hot water heating system then has become one of our goals, both because it does not require an actual conversion of solar energy to electricty- therefore eliminating the storage problem and the DC to AC conversion problem, and because the load is relatively consistantUsing solar power to heat water is a use of solar energy that makes a lot of sense for a house like ours as it is in a location that does experience a good number of gray days throughout the year and because heating is where we use the most energy.
+
Our current hot water system consists of an electric hot water heater that was installed in 1998.  After working on an energy audit of Miller Farm (our house) it has become clear that despite our relativily new water heater we still use a huge amount of energy to heat our water.  Installing a solar hot water heating system has therefore become one of our goals, both because it does not have the inherent complexties of a solar electric system, and because hot water heating is where we use the most electricityAlso using solar power to heat water makes a lot of sense for a house like ours, located in a region that experiences a good number of gray days throughout the year.
  
Currently we have two retired disel fuel tanks in our basement.  We are looking into how we prepare one or both of these tanks for use in our solar water system.  We want to install a bladder in the tank in order to use it to store water, but protect it from the disel fuel residue.
+
The following pages detail our research and development.
  
Needed additions:formula for figuring out how long water needs to be in the pipes at different exterior temperatures in order to be shower temperature.
+
*[http://wiki.cs.earlham.edu/index.php/Hot_h2o Hot Water Audit]
 
+
*[[hot_h20_experiment|Experimental Solor Hot Water System]]
==Experimental Solar Hot Water System==
+
*[[heat_bank_info|Information on Heat Bank Storage]]
 
+
*[[heat_exchanger_modeling|Copper Pipe Heat Exchanger Test]]
[http://wiki.cs.earlham.edu/images/8/82/ShwhSchematic.pdf Basic Design]
+
*[[mounting_information|Mounting the Solar Heater]]
 
+
*[[heat_bank_design|Our Heat Bank Design]]
*Supplies Needed
 
**(2) 1 1/4 inch female hot-water unit to hose connectors
 
**a pump
 
**hose?? (We found some hose in the green house that doesn't have end pieces)
 
**sealable barrel (the barrels out back don't have lids that we can open.  We need something sealed so that we don't turn the basement into a sauna)
 
**copper coil
 
**(2) hose to copper pipe connectors
 
**tube-o-silicon
 
**(long term) plexyglass or glass? and aluminum frame materials.
 
 
 
*Supplies Purchased
 
**12v Ag Sprayer Pump [http://www.flojet.com/prodInfoApp/itt_jsp/DisplayItemDetail.jsp?itemId=03501-503&companyId=FLOJET&catalogId=Agricultural&categoryId=FAGTP&typeId=FTP12  Product Information]
 
**2 Red River 50ft. farm hoses guarentteed up to 180F
 
**Teflon Pipe Tape
 
**lots of pipe/hose connectors
 
**flux
 
**25 ft 10-2# outdoor electrical wire
 
**30ft. soft copper tubing
 
 
 
*Supplies Purchaced-Addendum
 
**nails and bolts for PV stand
 
**self-liting butane torch
 
**12v connection cable for pump
 
**metal juction box and wire nuts
 
 
 
*Supplies Acquired
 
**scrap lumber
 
**duct tape
 
**30? gallon black plastic barrell
 
**various tools
 
**64 Watt solar panel
 
**solar hot water heating unit
 
 
 
*Resources
 
**Solar Panel Angle by time of year and latitude [http://www.homepower.com/files/pvangles.pdf click]
 
 
 
==Heat Bank Storage and Heat Transfer Information==
 
We plan on constructing a modified [http://www.heatweb.com/techtips/hbop3.htm Thermal Store] hot water system.  We will use a closed loop solar heating panel and heat exchanger to heat water in a recycled 250 gallon feul tank, then cold main water will be passed through a second heat exchanger in this "thermal battery" before entering the farm's standard electric water heater.  In this way the liquid in the solar heating loop, the liquid in the 250 gallon tank, and the  potable water being heated all remain isolated from each other.
 
 
 
*Heat Exchanger Information
 
**Ehren found a [http://shop.solardirect.com/product_info.php?cPath=22_74_77_118&products_id=488 manufacturer] that uses <i>24 sq ft of copper finned tubing ¾”</i> to heat the cold main water.  See the more detailed heat exchanger information at the bottom of the manufacturer's page.
 
**References
 
***http://www.eere.energy.gov/consumer/your_home/water_heating/index.cfm/mytopic=12930
 
***http://www.plumbingpages.com/featurepages/HWdpsThermstore.cfm
 
***http://www.greenshop.co.uk/solar/documents/Conus-Cubus-info.pdf
 
***http://www.heatweb.com/solar/solar.html
 
***http://www.dhtnet.com/index.htm
 
 
 
==Copper Pipe Heat Exchanger Test==
 
*Working with the Test Data
 
**We ran three tests using a 12" capped off piece of copper pipe filled with cold tap water and a 5 gallon bucket filled with hot water at three different temperatures. Ehren held the pipe in the bucket with a pair of tongs while Colin, Dan, and Kate recorded the temperature every three seconds using a digital thermometer carefully inserted into the pipe with plastic spacers so that it didn't touch the sides. Colin created graphs of the change in temperature inside the copper pipe over time.  They can be found at http://cs.earlham.edu/~hip/hip/databaseInterface/
 
**The 12" piece of 3/4" diameter copper pipe holds approximately 112 ml of water.  We have [http://wiki.cs.earlham.edu/index.php/Labs#Average_GPM_of_shower estimated] that the typical hot to cold water water ratio for a shower at Miller Farm is 4:1 and the total flow rate is 2.25 gal/min.  We can therefore assume that the we have a hot water flow rate of approximately 1.8 gal/min. = 6814 ml/min = 114 ml/s. This means that 112 ml will travel through a foot of copper pipe in 112 ml/(114 ml/s) = 0.98 seconds.
 
**Now, Ehren played around with graphs of exponential functions and found that T=95-23*e^(-s/80), where T is temp. and s is time in sec., reflects (pretty well--we can certainly improve on this) the graph of the experimental data we collected in the first run of the experiment.  Since the water for this experiment was about 97 degrees Fahrenheit and would most likely reflect the temperature of our storage tank in the mornings when folks are taking showers, lets see if we can scale an exchanger to match these findings.  Our limiting factors are space in the tank, and price.  The copper pipe costs a little less then $3.00 per foot.  Since we'll need to buy some connectors let's just say an average of $3.00 per foot for the heat exchanger.  Modifying our formula slightly we should find that Temp. Increase(TI) = 23-23*e^(-s/80).  So, we can now find a formula that relates Temp. Increase to Length of Pipe, and Temp. Increase to Price: (Let L=length of pipe in feet and M=price in dollars).
 
 
 
***L = (1/.98)*s = 1.02*s => s = L/1.02
 
***and M = 3*L => L = M/3 => s = M/3.06 
 
***so, TI = 23-23*e^(-(L/1.02)/80) = 23-23*e^(-(M/3.06)/80) 
 
***Also, note that s = 80*ln(-23/(TI-23)), where 1/(TI-23) < 0. So given a desired temp. increase we can calculate how much it will cost and how much pipe we would need.
 
***Thus, L=1.102*80*ln(-23/(TI-23)) and M=3.06*80*ln(-23/(TI-23)). 
 
 
 
**Now, if we take a look at dTI/dM = 0.094*(o.996)^M, we see that the slope of the change in Temp. over the change in Money is always less then 1.  This means that every additional degree of increase comes at a higher price.  So, we should  base our dicision on available space and the long term payback of preheating the water before it goes into the electic hot water heater. For example, if we want an increase the temperature of the main water by 10 degrees Fahrenheit we need 1.02*80*ln(-23/(10-23)) = 46.56 ft. of pipe for $139.67.  A 15 degree increase would require about 86.17 ft. at a cost of $258.52.
 

Latest revision as of 21:32, 28 September 2006

Developing a Solar Hot Water System at Miller Farm

Our current hot water system consists of an electric hot water heater that was installed in 1998. After working on an energy audit of Miller Farm (our house) it has become clear that despite our relativily new water heater we still use a huge amount of energy to heat our water. Installing a solar hot water heating system has therefore become one of our goals, both because it does not have the inherent complexties of a solar electric system, and because hot water heating is where we use the most electricity. Also using solar power to heat water makes a lot of sense for a house like ours, located in a region that experiences a good number of gray days throughout the year.

The following pages detail our research and development.