Difference between revisions of "Cluster:Netgear GBIC issues"
Jump to navigation
Jump to search
Line 30: | Line 30: | ||
* GBIC 1 in port 11 on SW0, GBIC 3 in port 11 on SW1, other GBICs depopulated: Good | * GBIC 1 in port 11 on SW0, GBIC 3 in port 11 on SW1, other GBICs depopulated: Good | ||
* GBIC 1 in port 11 on SW1, GBIC 3 in port 11 on SW0, other GBICs depopulated: | * GBIC 1 in port 11 on SW1, GBIC 3 in port 11 on SW0, other GBICs depopulated: | ||
+ | Good | ||
+ | * GBIC 1 in port 11 on SW1, GBIC 4 in port 11 on SW0, other GBICs depopulated: Good | ||
+ | * GBIC 1 in port 11 on SW0, GBIC 4 in port 11 on SW1, other GBICs depopulated: Good | ||
+ | * GBIC 1 in port 12 on SW0, GBIC 4 in port 12 on SW0, other GBICs depopulated: Good | ||
+ | * GBIC 1 in port 12 on SW1, GBIC 4 in port 12 on SW1, other GBICs depopulated: Good | ||
+ | * GBIC 2 in port 11 on SW0, GBIC 3 in port 11 on SW1, other GBICs depopulated: Pauses | ||
+ | * GBIC 2 in port 11 on SW1, GBIC 3 in port 11 on SW0, other GBICs depopulated: Pauses | ||
=== Bonded channel === | === Bonded channel === |
Revision as of 14:33, 23 June 2005
Contents
The symptoms
Port trunking on the cairo Netgear GSM712 GBIC ports causes frequent, repeatable delays of a few seconds for no obvious reason. Delays on a single GBIC/pair of GBICs might also be repeatable.
Things to remember
- Is LACP stable?
- Do we need LACP for port trunking?
- Is STP/RSTP on Netgear products stable?
- Could we try backing down to an earlier firmware? (We did a jump from 2.2.0→2.6.0 recently.)
Things I've tried
- Auto LACP enabled/disabled
- STP/RSTP/No spanning-tree
- Swapping cables
- Swapped top GBIC
- Swapped bottom GBICs
- Bad port 12?
- Marked all GBIC modules with identifying scratches.
Tests
Single channel
- GBIC 1 in port 11 on SW0, GBIC 2 in port 11 on SW1, other GBICs depopulated: Pauses
- GBIC 1 in port 11 on SW1, GBIC 2 in port 11 on SW0, other GBICs depopulated: Pauses
- GBIC 1 in port 12 on SW1, GBIC 2 in port 12 on SW0, other GBICs depopulated: Pauses
- GBIC 1 in port 12 on SW0, GBIC 2 in port 12 on SW1, other GBICs depopulated: Pauses
- GBIC 1 in port 12 on SW0, GBIC 3 in port 12 on SW1, other GBICs depopulated: Good
- GBIC 1 in port 12 on SW1, GBIC 3 in port 12 on SW0, other GBICs depopulated: Good
- GBIC 1 in port 11 on SW0, GBIC 3 in port 11 on SW1, other GBICs depopulated: Good
- GBIC 1 in port 11 on SW1, GBIC 3 in port 11 on SW0, other GBICs depopulated:
Good
- GBIC 1 in port 11 on SW1, GBIC 4 in port 11 on SW0, other GBICs depopulated: Good
- GBIC 1 in port 11 on SW0, GBIC 4 in port 11 on SW1, other GBICs depopulated: Good
- GBIC 1 in port 12 on SW0, GBIC 4 in port 12 on SW0, other GBICs depopulated: Good
- GBIC 1 in port 12 on SW1, GBIC 4 in port 12 on SW1, other GBICs depopulated: Good
- GBIC 2 in port 11 on SW0, GBIC 3 in port 11 on SW1, other GBICs depopulated: Pauses
- GBIC 2 in port 11 on SW1, GBIC 3 in port 11 on SW0, other GBICs depopulated: Pauses