Difference between revisions of "CEC Demo House"
Jump to navigation
Jump to search
m (→Inverter System) |
|||
Line 1: | Line 1: | ||
[[Image:cec-deck.jpg|Demo House Porch]] | [[Image:cec-deck.jpg|Demo House Porch]] | ||
− | == | + | == Solar and Wind Power System == |
− | === | + | |
− | [[http://www. | + | |
− | + | [[Image:Powersystem.jpg|Power system]] | |
− | * | + | |
+ | ===Third Sun=== | ||
+ | [[http://www.third-sun.com/ Third Sun]] | ||
+ | *Third Sun Solar & Wind Power, Ltd. - [[http://maps.google.com/maps?f=q&hl=en&q=Athens,+OH&btnG=Search Athens, OH]] | ||
+ | |||
+ | ===Vanner, Incorporated=== [[http://maps.google.com/maps?f=q&hl=en&q=Hilliard,+OH&btnG=Search Hilliard, OH]] | ||
+ | *[[http://www.vanner.com/htm/pro_01.htm?series_sku=3195365313155977&a=a&pt=3 Vanner RE 4500 Inverter]] | ||
+ | **Converts DC generated by solar and wind inputs to standard household AC. | ||
+ | |||
+ | ===Outback Power Systems=== | ||
+ | *'''Outback PSAC''' - Houses AC circuits for the system, including the AC output from the inverter and the AC input from the grid. | ||
+ | *'''Outback PSDC''' - Houses the breakers controlling the DC circuits. | ||
+ | *'''Trimetric Battery Meter''' - Metering display to monitor Amps, Battery Percent Full, and Volts. | ||
+ | |||
+ | [[http://www.outbackpower.com/MX60.htm MX60 MPPT Charge Controller]] | ||
+ | * - Arlington, VA - Model No. PSAC - Q1, 05 | ||
+ | *Regulates the flow of current to and from the battery bank. Maintains highest possible State Of Charge (SOC) while protecting the battery from deep discharge (by the loads) or extended overcharge (by the PV array). | ||
=== Wind Power === | === Wind Power === |
Revision as of 11:35, 24 January 2006
Contents
Solar and Wind Power System
Third Sun
- Third Sun Solar & Wind Power, Ltd. - [Athens, OH]
===Vanner, Incorporated=== [Hilliard, OH]
- [Vanner RE 4500 Inverter]
- Converts DC generated by solar and wind inputs to standard household AC.
Outback Power Systems
- Outback PSAC - Houses AC circuits for the system, including the AC output from the inverter and the AC input from the grid.
- Outback PSDC - Houses the breakers controlling the DC circuits.
- Trimetric Battery Meter - Metering display to monitor Amps, Battery Percent Full, and Volts.
- - Arlington, VA - Model No. PSAC - Q1, 05
- Regulates the flow of current to and from the battery bank. Maintains highest possible State Of Charge (SOC) while protecting the battery from deep discharge (by the loads) or extended overcharge (by the PV array).
Wind Power
- Bergey Wind Power - Norman, OK
Solar Power
Photovoltaic (PV) Array
- need this information
- Outback Power Systems - Arlington, VA - Model No. PSAC - Q1, 05
- Regulates the flow of current to and from the battery bank. Maintains highest possible State Of Charge (SOC) while protecting the battery from deep discharge (by the loads) or extended overcharge (by the PV array).
Current Appliances
Kitchen
Water Heater:
[Bosch Aquastar]
Bosch Hot Water - Model No. AQ 125-BLP-5
Fridge:
Kenmore
Model No. 253.66882502
AMPS-4.50
V-115
H-160
Stove:
Magic Chef (gas)
Stove Vent:
Broan Microteck System
Nortek Company
Model No. 41.000-K
four ceiling lights
Living Room
Thermostat:
Trane
Baystat 305
Tyler, Texas
one ceiling light
Bathroom
AM Conservation Group Spolier Showerhead
Model No. LM39709
lights?
Back Hall
two ceiling lights
sink